The rapid migration of IT loads, the difference in the heat density of the rack, and the coupling operation of equipment are easy to cause local overheating of the data centre and excessive cooling in other areas. Focussing on this supply and demand deviation, we build an energy-saving control strategy based on the perception of the Internet of Things (IoT), and use the rack inlet and outlet temperature, IT power, channel pressure difference, return air parameters, chilled water temperature difference, flow, and equipment power as input. The edge node is responsible for time synchronisation, abnormal data repair, and thermal state reconstruction, and the prediction module estimates the short-term cold load and hot spot migration trend. The control layer adopts a double closed-loop structure that combines equipment rapid response and system rolling optimisation to dynamically adjust the air supply temperature, fan speed, pump frequency, valve opening, and water chiller unit load rate, and embeds the upper temperature limit, minimum flow rate, start-stop interval, actuator change rate, and communication fault constraints. The virtual cold station with public operation data and actual measurement data calibration is used to compare the differences between fixed setting values, PID, and perception-driven control in refrigeration energy consumption, thermal safety, control fluctuations, and prediction errors.
Internet of Things (IoT); data center cooling; energy-saving control; thermal state estimation; model predictive control
[1] Zhang Q, Meng Z, Hong X, et al. A survey on data center cooling systems: technology, power consumption modeling and control strategy optimization. J Syst Archit. 2021;119:102253.
[2] Wang J, Tong X, Yue C, et al. Real-time temperature distribution reconstruction via linear parameter-varying state-space model and Kalman filter in rack-based cooling data centers. Build Environ. 2023;242:110601.
[3] Mirhoseininejad S, Badawy G, Down DG, et al. A data-driven, multi-setpoint model predictive thermal control system for data centers. J Netw Syst Manage. 2021;29:7.
[4] Mahbod MHB, Chng CB, Lee PS, et al. Energy saving evaluation of an energy efficient data center using a model-free reinforce-ment learning approach. Appl Energy. 2022;322:119392.
[5] Deng W, Wang J, Yue C, et al. Model-based control strategy with linear parameter-varying state-space model for rack-based cooling data centers. Energy Build. 2024;319:114528.
[6] Lu R, Li X, Chen R, et al. An alternative reinforcement learning (ARL) control strategy for data center air-cooled HVAC systems. Energy. 2024;308:132977.
[7] Lin J, Lin W, Lin W, et al. Multi-objective cooling control optimization for air-liquid cooled data centers using TCN-BiGRU-Attention-based thermal prediction models. Build Simul. 2024;17(12):2145-2161.
[8] Wu S, Zheng W, Wang Z, et al. AlphaDataCenterCooling: a virtual testbed for evaluating operational strategies in data center cooling plants. Appl Energy. 2025;380:125100.
[9] Kahil H, Sharma S, Välisuo P, et al. Reinforcement learning for data center energy efficiency optimization: a systematic literature review and research roadmap. Appl Energy. 2025;389:125734.
Energy-saving Control Strategy for Data Center Cooling System Based on Internet of Things (IoT) Perception
How to cite this paper: Xinyi Sun. (2026) Energy-saving Control Strategy for Data Center Cooling System Based on Internet of Things (IoT) Perception. Advances in Computer and Communication, 7(3), 196-200.
DOI: http://dx.doi.org/10.26855/acc.2026.09.017